FSP300-70PFL(SK) |
|
Feature :
- Meet 80 Plus Bronze
- Built-in Active PFC Function
- High Efficiency
- Low Ripple & Noise
- With OVP , OCP , and SCP Protection
|
Safety Approval
|
FSP300-70PFL Datasheet |
INPUT SPECIFICATION
Input Voltage: |
90 - 264Vac |
Input Frequency: |
47 - 63Hz |
Input Current: |
Max.4.0A @ 115V , Max.2.0A @ 230V: FSP250-70PFL |
|
Max.6.0A @ 115V , Max 3.0A @ 230V: FSP300-70PFL |
|
Max.7.0A @ 115V , Max 3.5A @ 230V: FSP350-70PFL |
|
Max.8..0A @ 115V , Max 4.0A @230V: FSP400-70PFL / FSP460-70PFL |
Earth leakage current: |
Max.3.5mA @ 264 Vac / 60Hz |
|
OUTPUT SPECIFICATION
Output Voltage / Current: |
See Product Series List |
Output Regulation Load: |
+3.3v , +5V , +12V , 24V , 5Vsb: +-5% |
|
-12V: +-10% |
Ripple and Noise: |
+3.3V , +5V , +5Vsb: 50mVp-p / +12V , -12V: 120mVp-p |
|
-5V: 100mVp-p / +24V: 240mVp-p |
Output Rise Time: |
115V-rms / 230V-rms +5V: 20ms Maximum |
Over Voltage Protection: |
+3.3Vdc ooutput : Protection point 3.7V - 4,8V |
|
+5Vdc output: Protection point 5.7V - 7.0V |
|
+12Vdc output: Protection point 13.3V - 16V |
Short Circuit Protection: |
Output short circuit is defined to be a short circuit load of less than 0.1 ohm |
Hold Up Time: |
Min 13mS @ 115Vac / 230Vac , Full Load / FSP250-70PFL , FSP300-70PFL |
|
Min 15mS @ 115Vac / 230Vac , Full load / FSP350-70PFL, FSP400-70PFL |
|
ENVIRONMENTAL
Operating Temperature: |
0°C + +50°C |
Storage Temperature: |
-20°C - +80°C |
Operating Humidity: |
5-85% , RH , Non-Condensing |
Storage Humidity: |
5-95% , RH , Non-Condensing |
MTBF: |
Min.100.000 hours at full load at 25°C ambient , predicated by MIL-HDBK-217F |
|
EMC & Safety
Safety Standard: |
EN61000-3-2 |
EMI: |
FCC part 15 Subpart J , class B 115Vac operation |
|
CISPR 22 Class B 230Vac operation |
|
Series List
Model Name |
Total Output Watt. |
Output Current |
Dimension (mm) |
+3.3V |
+5V |
+12V1 |
+12V2 |
-12V |
-5V |
+5Vsb |
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
L |
W |
H |
FSP300-70PFL |
300W |
0.3 |
19 |
0.5 |
16 |
0.5 |
17 |
0.5 |
17 |
0 |
0.5 |
0 |
0.3 |
0.1 |
3 |
140 |
150 |
86 |
|
Note:
"-12V,+3.3V,+5V,+12V will have the regulation±10% when all load take off. FSP250-70PFL: The +3.3V +5V +12V1 and 12V2 total output shall not exceed 90watts. The +3.3V and +5V total output shall not exceed 110watts and total output shall not xceed 250watts. FSP300-70PFL: The +3.3V +5V +12V1 and 12V2 total output shall not exceed 105watts. The +3.3V and +5V total output shall not exceed 110watts and total output shall not xceed 300watts. FSP350-70PFL: The +3.3V +5V +12V1 and 12V2 total output shall not exceed 105watts. The +3.3V and +5V total output shall not exceed 110watts and total output shall not xceed 350watts. FSP400-70PFL: The +3.3V +5V +12V1 and 12V2 total output shall not exceed 110watts. The +3.3V and +5V total output shall not exceed 110watts and total output shall not xceed 400watts. FSP460-70PFL: The +3.3V +5V +12V1 and 12V2 total output shall not exceed 120watts. The +3.3V and +5V total output shall not exceed 110watts and total output shall not xceed 460watts."
Price without AC cord |
|
|
|
|