FSP600-80PSA(SK) / FSP700-80PSA(SK) |
 
|
Feature :
- Meet 80 Plus BRONZE
- Build in Active PFC Function
- High Efficiency
- Low Ripple & Noise
- With OVP, OCP and SCP Protection
|
Safety Approval
    
|
FSP600-80PSA / FSP700-80PSA: click for Datasheet download |
INPUT SPECIFICATION
Input Voltage: |
90 - 264Vac |
Input Frequency: |
47 - 63Hz |
Input Current: |
Max. 10.0A @ 115V, Max. 5.0A @ 230V : FSP600-PSA
Max. 12.0A @ 115V, Max. 6.0A @ 230V : FSP700-PSA |
Earth leakage current: |
Max.3.5mA @ 264 Vac / 60Hz |
|
OUTPUT SPECIFICATION
Output Voltage / Current: |
See Product Series List |
Output Regulation Load: |
+3.3V, +5V, +12V, 5VSB : ±5% -12V: ±10% |
Ripple and Noise: |
+3.3V, +5V, +5VSB: 50mV p-p / +12V, -12V: 120mV p-p |
Output Rise Time: |
115V-rms/230V-rms + 5V: 20ms Maximum 115V-rms/230V-rms +12V: 20ms Maximum |
Over Voltage Protection: |
- 3.3Vdc output: Protection point 3.9V~4.5V
- +5Vdc output: Protection point 5.7V~6.5V
- +12Vdc output: Protection point 13.3V~16.7V
|
Short Circuit Protection: |
Output short circuit is defined to be a short circuit load of less than 0.1 ohm |
Hold Up Time: |
Min. 16mS @115Vac/230Vac, Full Load |
ENVIROMENTAL |
|
Operating Temperature |
0°C~50°C |
Storage Temperature |
- 20°C~80°C |
Operating Humidity |
10~90%, RH, Non-Condensing |
Storage Humidity |
5~95%, RH, Non-Condensing |
MTBF |
Min. 100,000 hours at full load at 25°C ambient, predicated by MIL-HDBK-217F |
|
EMC & Safety
Safety Standard: |
EN60950-1 UL60950-1 |
EMI: |
EN55022, Class B Conducted / Class B Radiated FCC Part15, Class B |
|
Series List
Model Name |
Total Output Watt. |
Output Current |
Dimension (mm) |
+3.3V |
+5V |
+12V1 |
+12V2 |
+12V3 |
+12V4 |
-12V |
+5VSB |
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
L |
W |
H |
FSP600-80PSA |
600W |
1.5 |
25 |
1 |
25 |
1 |
16 |
1 |
16 |
1 |
16 |
0.5 |
16 |
0 |
0.5 |
0.1 |
4 |
140 |
150 |
86 |
FSP700-80PSA |
700W |
1.5 |
24 |
1 |
30 |
1 |
16 |
1 |
16 |
1 |
16 |
0.5 |
16 |
0 |
0.5 |
0.1 |
4 |
140 |
150 |
86 |
|
Note:
-12V,+3.3V,+5V,+12V will have the regulation±10% when all load take off.
FSP600-80PSA:
(1)Maximum continuous tatal DC output should exceed 600W
(2)Maximum continuous combined load on +3.3VDC and +5VDC output shall not exceed 150W
(3)Maximum combined for the 12V output shall be 48A
FSP700-80PSA:
(1)Maximum continuous tatal DC output should exceed 700W
(2)Maximum continuous combined load on +3.3VDC and +5VDC output shall not exceed 170W
(3)Maximum combined for the 12V output shall be 56A
Price without AC cord |
|
|
|
|