DC Output spec.....
Output Voltage |
Output Current Min. |
Output Current Max. |
Regulation Load |
Regulation Line |
Output Ripple & Noise Max.[P-P] |
+5V |
1 |
32.00 |
±5% |
±1% |
50mV |
+12V |
1 |
65 |
±5% |
±1% |
120mV |
-12V |
0 |
0.8 |
±5% |
±1% |
120mV |
+3.3V |
1.0 |
32 |
±5% |
±1% |
50mV |
+5VSB |
0.1 |
3.5 |
±5% |
±1% |
50mV |
- REMARKS:
1.TOTAL OUTPUT OF +5V & +3.3V NOT EXCEED 190W
2.TOTAL OUTPUT POWER NOT EXCEED 800W
Features
* TEMPERATURE RANGE: OPERATING 0℃ --- 40℃, STORAGE –20℃ --- 80℃
* HOLD UP TIME: DC OUTPUT 12V MUST BE MAINTAIN 16 ms IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE
* EFFICIENCY: TYPICAL >80% AT 115V, 25%~100% MAX LOAD
* POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
* OVER POWER PROTECTION: 100~160%
* OVER VOLTAGE PROTECTION: +5V→5.7~6.5V, +3.3V→3.9~4.7V, +12V→13.3~14.3V
* OVER CURRENT PROTECTION: +3.3V→35.2~51.2A, +5V→35.2~51.2A, +12V→71.5~104A
* SHORT CIRCUIT PROTECTION: +12V, -12V, +5VSB
* EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
* FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL
* SAFETY: TO MEET UL, TUV IEC-60950, RFI/EMI STANDARDS
* REMOTE ON/OFF CONTROL
* COOLING: TWO 40 mm DC FANS (MODULE)
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS. |